The information presented on this website is informational only and does not necessarily reflect the current condition of the building or property. The fact that a permit was issued does not confirm that work was performed or performed in accordance with that permit and the requirements of the Municipal Code. Information on inspections and violations reflect conditions found by the inspector at the time of the inspection and not the current status of those violations or current condition of the property. The absence of violations on this website does not mean a building or property is in compliance with the requirements of the Municipal Code. Certain violations may be referred to the City's Department of Law for enforcement proceedings in the Department of Administrative Hearings or the Circuit Court of Cook County, and records of those proceedings may be obtained from the Department of Administrative Hearings or Clerk of the Circuit Court, respectively.


ADDRESS : 500  W   DIVERSEY  PKWY
 

COMPLAINT INSPECTION # 9901402

VIOLATION BUILDING CODE CITATION VIOLATION DETAILS
IR0000 Employ licensed architect or registered structural engineer to prepare written report showing structural condition of exposed metal structure and support. (13-96-830, 13-96-840, 13-96-860) exposed metal letter
IR0055 Protect metal structural members of fire escape against corrosion, and to scrape and paint every 3 years. (13-160-650) protect metal members
IR0057 Repair exposed metal structures according to structural engineering report. (13-96-820 thru 13-96-870) engineer report
IR0070 Relocate steel bands to original position on water tank. (13-96-420, 13-96-876) water tank bands
IR0071 Submit 2 copies of structural engineering report prepared, signed, and sealed by licensed architect or registered structural engineer about water tank. (13-96-830, 13-96-840, 13-96-850, 13-96-860, 13-96-870) engineer report